Net.Time Ω is a modular 4-port GbE clock (TCXO/OCXO/Rb) that meets most industry requirements for WAN or LAN timing. Supports PTP (Telecom & Power), NTP, PRP, ToD, PPS, IRIG-G-B, DCF77, SyncE, MHz, T1/E1, ASCII, Alarms (Electronic & Mechanic relays)

BARCELONA JUNE.11.2024

Net.Time Ω

Net.Time Ω (Omega) is a 4 Ports PTP/NTP/SyncE clock that allows multiple configurations to meet the timing requirements of any industry, including utilities, data centres, railways and air traffic control. The result is always a reliable and fault-tolerant solution to reference loss, network outages and power failures. At the same time, Net.Time Ω simplifies migration to PTP without abandoning investments in NTP, IRIG-B or BITS, thus facilitating the integration, interaction/translation of all types of signals, profiles or protocols.

Fig 1. Net.Time Ω universal, flexible, fault tolerant and powerful up to million NTP transactions / sec and 1024 unicast PTP clients.

Universal Protocol / Profile translator

Net.Time is very flexible as it accepts multiple clock references to discipline the internal circuitry. GNSS is the default and most obvious reference, but signals such as PTP, NTP, SyncE, ToD, IRIG-B, even MHz, E1/T1 can also be used as backup time references, in case the first reference fails or in case of GNSS spoofing. Everything continues as before, without loss of phase or time of the output signals. It can also translate the PTP profiles, e.g. be disciplined by the PTP telecom profile while offering PTP synchronisation with the power profile.

Fig 2. Time flexibility means that any in/out combination is possible.

Key features
  • Universal Timing Protocol and PTP profile translator
  • Modular: seven module to satisfy any technical demand on timing
  • Fault Tolerant to Power, Time and Network pitfalls
  • Optional Atomic Rubidium oscillator
  • Up to 4 x Ports 1Gb/s (opt/ele)
  • NTP Server up to 1,000,000 (million) transactions per second
  • Profiles: Telecom, Power, Utility profiles up to 1024 unicast clients
  • Simultaneous PTP + NTP + SyncE
  • PRP for PTP and NTP
  • PTP, NTP, SyncE, ToD, PPS, T1/E1, SyncE, IRIG-B, MHz, DCF77, and propierary protocols
  • Carrier-class: 2 x Vac / Vdc
  • +85ºC fan-less operation
  • Rubidium Plus / Rubidium / OCXO / TCXO oscillator
  • Roles: GrandMaster, Boundary, Slave
  • Optional Display+ Keyboard
  • RADIUS and TACACS+

Fig 3. Net.Time Omega applications and timing requirements.

 

Modular architecture

User customizable timing modules:

RIC-50

  • 5 x BNC / ST: IRIG-B, PPS, MHz
  • 4 x BNC: IRIG-B, PPS, MHz
  • 1 x BNC: DCF77, IRIG-B

 

 

RIC-52

  • 4 x RJ48: ToD, IRIG-B, ASCII
  • 4 x BNC: IRIG-B, PPS, MHz
  • 1 x BNC: IRIG-B, DCF77

 

 

RIC-54

  • 4 x BNC / ST: IRIG-B, PPS, MHz
  • 1 x BNC: IRIG-B1XX, DCF77
  • Terminal Block: IRIG-B, ASCII, PPS, PPS, 2 x Alarms (Mechanic relay)

 

RIC-56 (BNC)

  • 5 x BNC / SMA: 10 MHz (sine)
  • 4 x BNC / SMA: IRIG-B, PPS, 1.5 / 2.0 / 5 / 10 MHz (square)
  • 1 x BNC / SMA: IRIG-B1XX, DCF77

 

RIC-56 (SMA)

  • 5 x BNC / SMA: 10 MHz (sine)
  • 4 x BNC / SMA: IRIG-B00X, PPS, 1.544 / 2.048 / 5 / 10 MHz (square)
  • 1 x BNC / SMA (T5): IRIG-B, DCF77

 

RIC-82

  • 5 x BNC / ST: IRIG-B, PPS
  • Terminal Block: IRIG-B, PPS, ASCII, 2 x Alarms (Mechanic relay)

 

 

RIC-84

  • 5 x BNC / ST: IRIG-B, PPS
  • Terminal Block: IRIG-B, PPS, ASCII, 2 x Alarms (Mechanic relay)

 

 

 RIC-152

 

 

 

 

  • 2 x RJ45: PTP, NTP, SyncE
  • 2 x SFP: PTP, NTP, SyncE
  • 4 x RJ48: IRIG-B00X, ToD (NMEA, G.8271)/EH90, ASCII
  • 4 x BNC / ST: IRIG-B00X, PPS, 1.544 / 2.048 / 5 / 10 MHz
  • 1 x BNC: IRIG-B1XX, DCF77
  • Terminal Block: PPS, 2 x Alarms (Electronic and Mechanic relays)